Any feedback?
Please rate this page
(literature.php)
(0/150)

BRENDA support

Literature summary extracted from

  • Xiong, G.; Luo, Y.; Jin, S.; Maser, E.
    Cis- and trans-regulatory elements of 3alpha-hydroxysteroid dehydrogenase/carbonyl reductase as biosensor system for steroid determination in the environment (2009), Chem. Biol. Interact., 178, 215-220.
    View publication on PubMed

Application

EC Number Application Comment Organism
1.1.1.50 analysis replacement of hsdA gene by the green fluorescent protein gene inserted downstream from the hsdA regulatory region and use of the resulting strain as fluorescence based biosensor system for steroid determination. With this cell-based system, testosterone can be determined in a range between 57 and 450 ng/ml, estradiol between 1.6 and 12.8 ng/ml, and cholesterol between 19.3 and 154.4 ng/nl. The sensitivity of this bioassay can be further increased by using only the cytosol of the mutant. With the resulting cell-free system testosterone is determined in a range between 28 and 219 pg/ml, estradiol between 0.029 and 0.430 fg/ml, and cholesterol between 9.7 and 77.2 fg/ml. The recovery ratio of the extraction is around 95% and the maximum fluorescence signals are obtained as early as after 30 min. Limitations of the established steroid biosensor system are quenching at higher steroid concentrations and the relatively high background of fluorescence Comamonas testosteroni
1.1.1.50 environmental protection the mutant Comamonas testosteroni strain CT-GFP5-1 can be used as a sensitive biosensor system for steroid determination in the environment Comamonas testosteroni

Organism

EC Number Organism UniProt Comment Textmining
1.1.1.50 Comamonas testosteroni
-
-
-
1.1.1.50 Comamonas testosteroni P80702
-
-

Synonyms

EC Number Synonyms Comment Organism
1.1.1.50 3alpha-HSD/CR
-
Comamonas testosteroni
1.1.1.50 3alpha-hydroxysteroid dehydrogenase/carbonyl reductase
-
Comamonas testosteroni
1.1.1.50 hsdA
-
Comamonas testosteroni

Expression

EC Number Organism Comment Expression
1.1.1.50 Comamonas testosteroni several fold induction of expression in the presence of steroid substrates up

General Information

EC Number General Information Comment Organism
1.1.1.50 physiological function replacement of hsdA gene by the green fluorescent protein gene inserted downstream from the hsdA regulatory region and use of the resulting strain as fluorescence based biosensor system for steroid determination. With this cell-based system testosterone can be determined in a range between 57 and 450 ng/ml, estradiol between 1.6 and 12.8 ng/ml, and cholesterol between 19.3 and 154.4 ng/nl. The sensitivity of this bioassay can be further increased by using only the cytosol of the mutant. With the resulting cell-free system testosterone is determined in a range between 28 and 219 pg/ml, estradiol between 0.029 and 0.430 fg/ml, and cholesterol between 9.7 and 77.2 fg/ml. The recovery ratio of the extraction is around 95% and the maximum fluorescence signals are obtained as early as after 30 min. Limitations of the established steroid biosensor system are quenching at higher steroid concentrations and the relatively high background of fluorescence Comamonas testosteroni