Any feedback?
Please rate this page
(literature.php)
(0/150)

BRENDA support

Literature summary for 1.14.13.231 extracted from

  • Besharati, M.; Hamedi, J.; Hosseinkhani, S.; Saber, R.
    A novel electrochemical biosensor based on TetX2 monooxygenase immobilized on a nano-porous glassy carbon electrode for tetracycline residue detection (2019), Bioelectrochemistry, 128, 66-73 .
    View publication on PubMed

Application

Application Comment Organism
analysis construction of an enzyme-based biosensor for sensitive determination of tetracycline using TetX2 immobilized on modified glassy carbon electrodes. The electrode as a biosensing interface based on the oxygen reduction peak current resuls in a linear range response from 0.5 to 5 microM with a detection limit of 18 nM Bacteroides thetaiotaomicron

Organism

Organism UniProt Comment Textmining
Bacteroides thetaiotaomicron Q93L51
-
-

Synonyms

Synonyms Comment Organism
TetX2
-
Bacteroides thetaiotaomicron