Any feedback?
Please rate this page
(literature.php)
(0/150)

BRENDA support

Literature summary for 1.1.3.17 extracted from

  • Kudo, H.; Goto, T.; Saito, T.; Saito, H.; Otsuka, K.; Mitsubayashi, K.
    Biochemical sniffer with choline oxidase for measurement of choline vapour (2008), Microchim. Acta, 160, 421-426.
No PubMed abstract available

Application

Application Comment Organism
biotechnology development and application of enzyme-based gas sensor Alcaligenes sp.

Natural Substrates/ Products (Substrates)

Natural Substrates Organism Comment (Nat. Sub.) Natural Products Comment (Nat. Pro.) Rev. Reac.
choline + O2 Alcaligenes sp.
-
betaine aldehyde + H2O2
-
?

Organism

Organism UniProt Comment Textmining
Alcaligenes sp. P16101
-
-

Source Tissue

Source Tissue Comment Organism Textmining
commercial preparation
-
Alcaligenes sp.
-

Specific Activity [micromol/min/mg]

Specific Activity Minimum [µmol/min/mg] Specific Activity Maximum [µmol/min/mg] Comment Organism
additional information
-
sensor consisting of Clark-type dissolved oxygen electrode and choline oxidase immobilized membrane, choline concentration measured by the oxygen consumption induced by an enzyme reaction of choline oxidase, calibration curves for choline in the liquid and gas phases, response time for choline vapour 15% slower than that of biosensor for choline solution Alcaligenes sp.

Substrates and Products (Substrate)

Substrates Comment Substrates Organism Products Comment (Products) Rev. Reac.
choline + O2
-
Alcaligenes sp. betaine aldehyde + H2O2
-
?
choline + O2 enzyme-based gas sensor, responses and calibration properties of the sensor for both of liquid and gaseous phases, various choline concentrations Alcaligenes sp. betaine aldehyde + H2O2
-
?

pH Optimum

pH Optimum Minimum pH Optimum Maximum Comment Organism
8
-
choline determination in the liquid phase at Alcaligenes sp.