Any feedback?
Please rate this page
(literature.php)
(0/150)

BRENDA support

Literature summary for 1.7.2.2 extracted from

  • Zhang, Z.; Xia, S.; Leonard, D.; Jaffrezic-Renault, N.; Zhang, J.; Bessueille, F.; Goepfert, Y.; Wang, X.; Chen, L.; Zhu, Z.; Zhao, J.; Almeida, M.G.; Silveira, C.M.
    A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane (2009), Biosens. Bioelectron., 24, 1574-1579.
    View publication on PubMed

Application

Application Comment Organism
analysis development of a conductometric biosensor for nitrite detection using cytochrome c nitrite reductase immobilized on a planar interdigitated electrode. Under the optimum conditions at room temperature, the biosensor shows a fast response to nitrite with a linear range of 0.2–120 microM, a sensitivity of 0.194 microS per microM NO2?, and a detection limit of 0.05 microM. The biosensor also shows satisfactory reproducibility. When stored in potassium phosphate buffer at 4 ?C, the biosensor shows good stability over 1 month Desulfovibrio desulfuricans

Organism

Organism UniProt Comment Textmining
Desulfovibrio desulfuricans
-
strain ATCC 27774
-

Purification (Commentary)

Purification (Comment) Organism
-
Desulfovibrio desulfuricans

Source Tissue

Source Tissue Comment Organism Textmining